Hi all,
I'm fairly new to blade chassis/networking and have been tasked with setting up a M1000e with 12 blades with 4 mxl fabric switches splitting 4 VLANs across 2 VLT pairs (management & production in A2 & B1 / iSCSI & vMotion in A1 & B2). There's a port channel from fabric A2 & B1 to a TOR N4032 (which will be VLT paired as our new core network).
So far i have the management and production switches configured and i've got one blade server installed in slot 1 (m620). I see te 0/1 as up and on the default vlan (untagged) and both production and management (tagged).
Port Description Status Speed Duplex Vlan
Te 0/1 Up 10000 Mbit Full 1,405,410
Slot 1 has ESXi installed on it and if i run a ring test i get no responses from anything on the management or production VLANs.
If i check the mac address table on fabric B1 all i see is port channel (101) with no reference to the MAC address at te 0/1.
VlanId Mac Address Type Interface State
1 14:18:77:d9:16:b1 Dynamic Po 101 Active
1 14:18:77:d9:16:b2 Dynamic Po 101 Active
1 44:a8:42:3b:d0:23 Dynamic Po 101 Active
405 00:00:74:df:0a:3b Dynamic Po 101 Active
405 00:00:74:eb:79:64 Dynamic Po 101 Active
405 00:01:e8:8b:f0:be Dynamic Po 101 Active
405 00:0c:29:5c:d9:e3 Dynamic Po 101 Active
405 00:12:79:d6:a0:ea Dynamic Po 101 Active
405 00:12:79:d6:a0:eb Dynamic Po 101 Active
405 00:15:c5:ef:d9:ad Dynamic Po 101 Active
405 00:18:fe:69:fd:42 Dynamic Po 101 Active
405 00:19:b9:dd:dd:15 Dynamic Po 101 Active
405 00:19:b9:dd:dd:17 Dynamic Po 101 Active
405 00:19:b9:de:17:95 Dynamic Po 101 Active
405 00:19:b9:de:17:97 Dynamic Po 101 Active
405 00:1b:21:24:12:3b Dynamic Po 101 Active
405 00:20:4a:71:04:ae Dynamic Po 101 Active
405 00:20:4a:71:04:af Dynamic Po 101 Active
405 00:20:4a:71:04:b0 Dynamic Po 101 Active
405 00:20:4a:71:04:b1 Dynamic Po 101 Active
405 00:20:4a:71:04:b2 Dynamic Po 101 Active
405 00:20:4a:71:04:b3 Dynamic Po 101 Active
405 00:20:4a:71:04:b4 Dynamic Po 101 Active
I'm at a loss with why this would be. Does anyone have any ideas?