Hi, I have 2 N4032 switches installed on separate server racks.
They are inter-connected on Port 23 and 24. Servers in Rack1 can ping Switch1, Servers in Rack2 can ping Switch2. However, they cannot inter-ping, i.e., Servers in Rack1 cannot ping Servers in Rack2 ...
How can I make them inter-connected? Any ideas will be highly appreciated. Thanks in advance!
Switch 1
vlan 201
name "DMZ"
exit
vlan 202
name "DEV"
exit
vlan 203
name "INT"
exit
vlan 204
name "MGT"
exit
vlan 201-204
exit
...
interface Te1/0/23
channel-group 1 mode active
exit
!
interface Te1/0/24
channel-group 1 mode active
exit
!
interface port-channel 1
switchport mode trunk
switchport trunk native vlan 204
switchport trunk allowed vlan 202-204
exit
Switch 2
vlan 202
name "DEV"
exit
vlan 203
name "INT"
exit
vlan 204
name "MGT"
exit
vlan 202-204
exit
...
interface Te1/0/23
channel-group 1 mode active
exit
!
interface Te1/0/24
channel-group 1 mode active
exit
!
interface port-channel 1
spanning-tree guard root
switchport mode trunk
switchport trunk native vlan 204
switchport trunk allowed vlan 202-204
exit