Port Monitor issues Powerconnect 5424 Status notReady

$
0
0

I'm having some issues setting up a port monitor on one of the old switches that we have. My config is listed below along with what I am seeing from from the "show ports monitor" command after I have set the mirror up. From the documentation this looks very easy. Am I missing something?

 

testsw# show running-config
voice vlan oui-table add 0001e3 Siemens_AG_phone________
voice vlan oui-table add 00036b Cisco_phone_____________
voice vlan oui-table add 00096e Avaya___________________
voice vlan oui-table add 000fe2 H3C_Aolynk______________
voice vlan oui-table add 0060b9 Philips_and_NEC_AG_phone
voice vlan oui-table add 00d01e Pingtel_phone___________
voice vlan oui-table add 00e075 Polycom/Veritel_phone___
voice vlan oui-table add 00e0bb 3Com_phone______________
interface ethernet g12
port monitor g11
exit
iscsi target port 860 address 0.0.0.0
iscsi target port 3260 address 0.0.0.0
iscsi target port 9876 address 0.0.0.0
iscsi target port 20002 address 0.0.0.0
iscsi target port 20003 address 0.0.0.0
iscsi target port 25555 address 0.0.0.0
interface vlan 1
ip address 10.0.0.1 255.255.0.0
exit
hostname testsw

Default settings:
Service tag: 910WFH1

SW version 2.0.0.46 (date 14-Apr-2011 time 13:10:53)

Gigabit Ethernet Ports
=============================
no shutdown
speed 1000
duplex full
negotiation
flow-control off
mdix auto
no back-pressure

interface vlan 1
interface port-channel 1 - 8

spanning-tree
spanning-tree mode STP

qos basic
qos trust cos
testsw#


testsw# show ports monitor


Source Port Destination Port Type Status
----------- ---------------- ------- ----------
g11 g12 RX,TX notReady


testsw#