Power Connect 6224 Stack ID behavoir
Hi.I got 10x Power Connect 6224 stacked. Last night I added an 11th member.Question 1: As I understand we can hot add or remove members ? After I added the 11th member the stack ID of all switches...
View ArticleLong stack cables for N3048
Hi all,I need to know which are the stacking cable specifications, since I need to buy new (ang longer) stacking cables (the provided cables are only 0,25 m length.Do you have any specifications and/or...
View ArticlePower Connect 6224 IGMP Problem
Dear Folks,I face a igmp group membership lost issue for a while and I check my logs. it seems there is a problem at multicast table entries. Can Anyone help me about that issue? Last firmwares has not...
View ArticleFlapping port on a two port LAG connecting a single PowerConnect 6248 to a...
I am moving from a single core switch PowerConnect 6248 to a stacked core switch of 2 PowerConnect 6248s. In the interim, I would like to connect both the soon to be retired core switch (sw038) AND the...
View ArticlePowerconnect 6248 Inter-VLAN routing to gateway
I'm trying to use the 6248 as a layer 3 device for the two VLANs on a ESXi host. I can see inter-vlan routing is working OK as from the ESXi host, VLAN 10 and ping VLAN 20 and vice versa. The ESXi's...
View ArticleVery Simple Config on a 6248
I have the need to have 3 VLANs3 VLANs can't talk to each other.VLANs should be able to get to the internetMy gateway is a standard Linksys type of router with the IP of 192.168.1.1My Switches IP is...
View Article8024f how to turn of certain events from logging
HiI have a cluster of 8024f powerconnect switches. I log events to a sys log server, but I want to stop certain events from being loggedfor example<189> NOV 02 08:51:37 10.32.80.4-1...
View ArticleN2024P POE Cisco Wireless Access Point and
Hello Guys, I'm facing worried issue with some of Cisco AiroNet 1200 AP series, some of them are going down and disassociated from the Controller. If I logged into the switch and shut and no shut the...
View ArticleM1000e - Can Switch IO Modules Be Hot Removed?
I want to replace the 1GB modules with 10GB modules and I know that the IO modules can be hot added I want to make sure the reverse is true - that they can also be hot removed.Is this possible?
View ArticleDell PowerConnect 2824 dropping connections, odd led patterns
Hi,We are noticing on some of our Dell PowerConnect 2824 switches that our are devices connected to the switch suddenly get disconnected. Our devices form a small network with the switch, where we...
View ArticleDell PowerConnect 2824 Configuration Files
Hi,Can anyone tell me if the configuration files for Dell PowerConnect 2824 v1.0.0.44 are compatible with v1.0.0.45?Thanks,Bob
View ArticleDell Powerconnect 6224 DVLAN-Tunnelling (Q in Q)
I have two different sites, one is our datacenter and the other is our office.I want to be able to get access to the datacenter network from the office, I need the access for 2 vlan`s, the ISP has...
View ArticlePowerConnect M6220, 4.1.0.6, VxWorks 6.6 LOSING PACKETS ONLY ON MANAGEMENT
Hi,I'm new here and I already searched for a problem like mine, but I haven't found anything like that. I'm having problems on sending packets to my Switch Dell only in management , I already did all...
View ArticleNeed help to configure VLANs on powerconnect 5448
Hello world,i'm actually working on 2 PowerConnect 5448 switches but i'm quite lost in VLAN config.My arch :My needs are the following :- i have 2 different networks which have to be isolated in...
View ArticleConnecting Multiple Switches for best performance.
Hi I recently inherited a network mess. I have a Sonicwall NSA 3500 with a single LAN routing thru 4 switches and to 4 servers. I would like to increase the bandwidth between the switches using Link...
View ArticleDell Powerconnect 6248 - Running Config
How can I access the running config from the GUI? Would like to copy it to a txt file
View ArticleDELL 5548 show CPU utilitzation in stack mode
HI,My question is very simple: how can we show cpu utilization in stack mode of 5548?I know i can connect to master switch and issue the following command to check it's cpu1# sh cpu % Incomplete...
View ArticleDell N3000 link for IP-Phone not detected
Hi!Our Siemens Gigaset S450IP IP-Phones don't work on N3048. When a phone is connected no link is detected.Phones run on 10mbit half duplex.Any help would be appreciated!Regardsbsorg
View Articlelacp and PXE with powerconnect 7048
Hii have to installed several dozens of dell server.to do that we use well know software cobbler.this software use pxe to boot the server to initiate the install.But at the end the server will use for...
View ArticleMulticast traffic stop working on Power Connect 6248 and 6224
We have three Dell Power Connect on our network core. Two 6248 and one 6224 every one with a different network and aren't connected to each other. One of the 6248 have the firmware version 3.2.1.3 and...
View Article